MIS340-MIS343 QuickStep - NEMA34 Programmierbare integrierte ServoStep-Motoren mit Closed-Loop, Ethernet, Multiturn-Encoder

 


QuickStep, die integrierten ServoStep-Motoren von JVL.
Eine Fülle von Möglichkeiten in einer Serie der weltweit kompaktesten Schrittmotoren mit der höchsten Mikroschrittauflösung. Es stehen 4 Größen zur Verfügung.

 
MIS340 - 3.0/3.0Nm
MIS341 - 6.1/6.1Nm
MIS342 - 9.0/7.5Nm
MIS343 - 12.0/10.0Nm
 
Edelstahlwelle AISI303 serienmäßig bei allen Modellen

Optional:
 
MIS340-MIS343 QuickStep - Integrated Stepper Motors
JVL deliver sophisticated and ingenious electronic design of integrated stepper motors
JVL integrated Quick stepper motors with highly innovative solutions
JVL integrated Quick stepper motors with highly innovative solutions
MIS340-MIS343 QuickStep - Integrated Stepper Motors
 
 


 


Running
Torque
[Nm]*
Länge
[mm]
Welle
[mm]
Leistung Watt @72VDC* Gewicht
[kg]

Standard
MIS340C12
3.0
95.0
9.53 D-cut
190.49
1.96

MIS340C49
3.0
95.0
14 keyway (5x5)
190.49
1.96

MIS340C65
3.0
95.0
12.7 keyway (5x5)
190.49
1.96

MIS341C12
6.1
125.0
9.53 D-cut
322.37
3.06

MIS341C14
6.1
125.0
14 keyway (5x5)
322.37
3.06

MIS342C14
7.5
155.0
14 keyway (5x5)
332.53
4.06

MIS343C14
10.0
185.0
14 keyway (5x5)
296.21
5.16

*: Tolerance for torque and power is ±10%
Industrial Ethernet and Closed-loop Absolute multiturn encoder magnetic feedback encoder (H4).

 
Schrittmotor, Encoder und Elektronik wurden von JVL so entwickelt, dass sie eine geschlossene Einheit bilden, wobei Leistungstreiber, Controller, Ethernet und Wireless im Motor in einem geschlossenen Bereich mit einer Schutzart bis IP67 untergebracht sind. Alle Modelle sind standardmäßig mit Edelstahlwelle AISI303 ausgestattet.
 

 


QuickStep M12 Stecker Übersicht
Power 5-pol. Buchse
IO1-8 RS485 MFIO
17-polige Buchse
RS485
5-polige Buchse
RS485 + IO4
8-pol. Buchse
CANopen 2x5-pol. Buchse
SSI-Encoder 8-pol. Stecker
Ethernet 2x4-pol. Stecker
D-Code
MIS34xxyyQ5zz85 (Pre. Typ)
X X X X


MIS34xxyyP6zz85 (CANopen)
X X

X

MIS34xxyyQ9zz85 (SSI-Eingang)
X X
X
X
MIS34xxyyExzz85 (Ethernet)
X X



X
MIS34xxyyWxzz85 (Wireless)
X X




MIS34xxyyExzz85 (Ethernet + SSI)
X X


x
x
M12 Pin 1
P+ (12-80VDC)
IO1 B0+ (RS485)
IO1 CAN_SHLD IO5 Zero Set
TXO_P
M12 Pin 2 P+ (12-80VDC)
GND A0- (RS485)
IO2 Unbenutzt IO6 CNTDIR
RXO_P
M12 Pin 3
P- (GND)
IO2 B0+ (RS485)
IO3 CAN_GND A+ (Clock+)
TXO_N
M12 Pin 4
CVI (12-28VDC)
IO3 A0- (RS485)
GND CAN_H GND RXO_N
M12 Pin 5
P- (GND)
B1- (RS422)
GND B0- (RS485)
CAN_L B- (Data in-)
-
M12 Pin 6
- IO4 - A0+ (RS485)
- B+ (Data in+)
-
M12 Pin 7
- A1- (RS422)
- IO4 - A- (Clock-)
-
M12 Pin 8
- B1+ (RS422)
- CVO (out)
- CVO (out)
-
M12 Pin 9
- CVO (out)
- - - - -
M12 Pin 10
- A1+ (RS422)
- - - - -
M12 Pin 11
- IO5 - - - - -
M12 Pin 12
- IO6 - - - - -
M12 Pin 13
- IO7 - - - - -
M12 Pin 14
- IO8 - - - - -
M12 Pin 15
- A0+ (RS485)
- - - - -
M12 Pin 16
- GND - - - - -
M12 Pin 17
- B0- (RS485)
- - -
-
-
M12 Stecker Lötanschlüsse
WI1008-M12F5SS1
(nicht verfügbar)
WI1008-M12M5SS1
WI1008-M12M8SS1
WI1008-M12M5SS1 WI1008-M12FBSSI
(nicht verfügbar)
M12 Kabel 5m.
WI1000-M12F5T05N WI1009-M12M17T05N
WI1005-M12M8VM5V03N WI1000-M12M8T05N
WI1006-M12F5TM5T05N
WI1000-M12F8T05N
WI1046-M12M4S05R
zz=N0~Kein Encoder, H2~magnetischer Encoder, H3~Absolut-Encoder.

Choose between wireless Bluetooth, WLAN or Industrial Ethernet Profinet, Ethernet/IP, EtherCAT, Powerlink, MODBUS TCP/IP, SERCOS III, RS485 and PLC built-in are standard. 8IOA, SSI and pulse/direction




Industrial Ethernet Profinet, Ethernet/IP, EtherCAT, Powerlink, MODBUS TCP/IP, SERCOS III . Built in dual port Ethernet switch for simple wiring and cost reduction. Read more
SSI (RS485) Build in SSI interface for external incremental or absolute encoder. 5V balanced signals. Read more
CANBUS CANbus DS-301 with heartbeat/Node guarding/sync etc. Read more
MODBUS (RS485) RS485 interface for serial 2Mbit daisy chain communication for low cost solution. Read more
MACTALK (RS485) RS485 interface for live diagnostics, setup and user programming. Read more
PLC 8 input/output/analogue input allow highly advanced functions via the build in PLC. Read more
Gear Mode (RS422)
In this mode the QuickStep motor functions as in a step motor driver. The motor moves one step each time a voltage pulse is applied to the step-pulse input. Velocity, acceleration and deceleration are determined by the external frequency, but can be limited and controlled by the QuickStep motor. In addition, the QuickStep motor also provides a facility for electronic gearing at a keyed-in ratio.
Serial Mode (RS485)
In this mode the QuickStep motor’s registers contain the positions, velocities, accelerations, etc., required for the actual system. The registers can be selected and executed by a single byte sent via the serial interface. This mode provides maximum utilization of the QuickStep motor’s features since the QuickStep motor itself takes care of the entire positioning sequence.

Position and velocity Mode (RS485)
With command sent over the serial interface can position and velocity be changed. Various operating parameters can be changed continuously while the motor is running. This mode of operation is used primarily in systems where the Controller is permanently connected to a PC/PLC via the interface. It is also well suited for setting up and testing. The mode is also used when programming is made.

Outputs Up to 8 pcs high side for relay, PLC or brake control. 24VDC PNP high power 0,4A (peak 0,9A) each. Short circuit and reverse protected.
Inputs Up to 8 pcs 24VDC logic inputs that can we used for limit switch, homing, position capture, enable input, pulse/dir.
Analogue input Up to 8 pcs 0-5V 12bit that can we used in program for analogue to speed or position. Protected up to +-30VDC.
RS422 Input used for connection of external encoder, AB incremental signal or pulse and direction signal. 5VDC balanced signal A+.A-,B+.B-


 

 

 
 
 
 


 
All measurements are taken while the motors are in open loop mode.

MIS340 Power/Torque vs. Speed

MIS341 Power/Torque vs. Speed





(download)

(download)

MIS342 Power/Torque vs. Speed

MIS343 Power/Torque vs. Speed






(download)

(download)
 


 
 
 


 


 
 
 
 
 

Zum JVL YouTube-Channel
JVL Präsentationsvideo (vorläufig)
JVL Akademie
  • So wird ein integrierter JVL Motor angeschlossen und getestet
  • Closed-Loop lineare Bewegung
  • Closed-Loop Drehmoment


WEITERE EINZELHEITEN
 


 

DOWNLOAD

 
 
 
 
 
 
 
 
 
 
 
 
 

 


JVL A/S Deutschland Moltkestr. 24 DE-72762 Reutlingen Deutschland
Tel: +49 7121 1377260 Fax: +49 7121 1377317 E-mail: sales@jvl.dk
Copyright © JVL A/S - All Rights Reserved.

SEO & CMS System.


HTML5 | CSS3